Test Code DIA Diazepam and Metabolites, Serum
Reporting Name
Diazepam and metabolites, SUseful For
Assessing compliance
Monitoring for appropriate therapeutic level
Assessing diazepam toxicity
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Performing Laboratory

Specimen Type
Serum RedSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Red top (Serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum Red | Refrigerated (preferred) | 28 days |
Ambient | 28 days | |
Frozen | 28 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
Therapeutic concentrations
Diazepam: Not established
Diazepam and Nordiazepam: 100-2,500 ng/mL
Cutoff concentrations by liquid chromatography tandem mass spectrometry:
Diazepam: 10 ng/mL
Nordiazepam: 10 ng/mL
Oxazepam: 10 ng/mL
Temazepam: 10 ng/mL
Day(s) Performed
Wednesday
CPT Code Information
80299
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
DIA | Diazepam and metabolites, S | 49044-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
8629 | Diazepam | 3548-5 |
2475 | Nordiazepam | 3537-8 |
2459 | Diazepam and Nordiazepam | 16757-7 |
622868 | Oxazepam | 3886-9 |
622869 | Temazepam | 10343-2 |