Test Code ENTP Enterovirus, Molecular Detection, PCR, Plasma
Reporting Name
Enterovirus PCR, PUseful For
Aiding in diagnosing enterovirus infections using plasma specimens
This test should not be used to screen asymptomatic patients.
Method Name
Real-Time Polymerase Chain Reaction (PCR)/RNA Probe Hybridization
Performing Laboratory
 Mayo Clinic Laboratories in Rochester
 Mayo Clinic Laboratories in Rochester
Specimen Type
Plasma EDTAOrdering Guidance
This test will detect enterovirus but will not differentiate viruses in this family or provide serotyping information.
Specimen Required
Submit a raw clinical sample (not a culture isolate) for enterovirus polymerase chain reaction .
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube: Screw-capped, sterile container
Specimen Volume: 1 mL
Collection Instructions: Centrifuge blood collection tube and aliquot plasma into plastic vial.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
| Specimen Type | Temperature | Time | 
|---|---|---|
| Plasma EDTA | Refrigerated (preferred) | 7 days | 
| Frozen | 7 days | 
Reject Due To
| Gross hemolysis | Reject | 
Reference Values
Negative
Day(s) Performed
Monday through Sunday
CPT Code Information
87498
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value | 
|---|---|---|
| ENTP | Enterovirus PCR, P | 97151-5 | 
| Result ID | Test Result Name | Result LOINC Value | 
|---|---|---|
| 56068 | Enterovirus PCR, P | 97151-5 | 
 